  Datasheet File OCR Text:
  carling technologies, inc. 60 johnson avenue, plainville, ct 06062 email: sales @ carlingtech.com application support: team2 @ carlingtech.com phone: 860.793.9281 fax: 860.793.9231 www.carlingtech.com a-series a-series circuit breaker well known for their proven reliability, carling technologies a-series hydraulic magnetic circuit breakers are compact, temperature stable and designed for precision operation in oem markets requiring general purpose as well as full load amp applications. when front panel operation and aesthetics demand a clean, contemporary design, the visi-rocker or paddle actuators are ideally suitable. a sealed toggle actuator style is also available and ideal for harsh environment applications requiring additional sealing protection. optional rocker-guard and push- to-reset bezels, which help prevent inadvertent actuation, are also available. 1-6 poles; ratings from 0.02 to 50 amps, up to 277vac or 80vdc; ul recognized, ul listed, ul1500, ul1077, tuv, vde & csa product highlights: ? up to 50 amps in a compact size ? various actuator styles ? sealed metal toggle option tested to mil-prf-55629c. meets ip68 requirements typical applications: ? telecom/datacom ? marine ? military ? renewable energy ? generators & welder
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 2 | a-series circuit breaker - general specifcations *manufacturer reserves the right to change product specification without prior notice. electrical resistance per pole values from line to load terminals (values based on series trip circuit breaker) mechanical physical environmental designed and tested in accordance with requirements of specifcation mil-prf-55629 & mil-std-202 as follows: maximum voltage 277vac 50/60 hz, 80vdc current ratings standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. other ratings available - consult ordering scheme. standard voltage coils dc-6v, 12v; ac-120v, other ratings available, consult ordering scheme. auxiliary switch rating spdt; 10.1 a - 250vac, 1.0 a-65vdc/0.5 a - 80 vdc, 0.1a - 125vac (with gold contacts). insulation resistance minimum: 100 megohms at 500 vdc dielectric strength ul, csa - 1500v 60 hz for one minute between all electrically isolated terminals. a-series rocker circuit breakers comply with the 8mm spacing & 3750v dielectric requirements from hazardous voltage to operator accessible surfaces per en 60950 and vde 0805. resistance, impedance values from line to load terminal - based on series trip circuit breaker. endurance 10,000 on-off operations @ 6 per minute; with rated current & voltage. trip free all a-series circuit breakers will trip on overload, even when the actuator is forcibly held in the on position. trip indication the operating actuator moves positively to the off position when an overload causes the circuit breaker to trip. when mid-trip handle is specifed, the handle moves to the mid position on electrical trip of the circuit breaker. when mid-trip handle with alarm switch is specifed, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped. number of poles 1 - 6 poles (handle) and 1-3 poles (rocker) at 30 amps or less. 1 and 2 poles at 31 amps thru 50 amps. internal circuit confg. series, (with or without auxiliary switch), shunt and relay with current or voltage trip coils, dual coil, switch only with or without auxiliary switch. weight approximately 65 grams/pole. (approximately 2.32 ounces/pole) standard colors housing - black; actuator- see ordering scheme. shock withstands 100 gs, 6ms, sawtooth while carrying rated current per method 213, test condition i. instantaneous and ultra-short curves tested @ 90% of rated current. vibration withstands 0.060 excursion from 10-55 hz, and 10 gs 55-500 hz, at rated current per method 204c, test condition a. instantaneous and ultrashort curves tested at 90% of rated current. moisture resistance method 106d; ten 24-hour cycles @ + 25c to +65c, 80-98% rh.56 days @ +85c, 85% rh. salt spray method 101, condition a (90-95% rh @ 5% nacl solution, 96 hrs). thermal shock method 107d, condition a (five cycles @ -55c to +25c to +85c to +25c). operating temperature -40 c to +85 c pulse tolerance curves current (amps) tolerance (%) 0.10 - 5.0 15 5.1 - 20.0 25 20.1 - 50.0 35
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 3 a-series circuit breaker - general specifcations electrical tables table a: lists ul recognized & csa accepted confgurations and performance capabilities as a component supplementary protector. notes: 1 requires branch circuit backup with a ul listed type k5 or rk5 fuse (15a minimum) at no more than 4 times the rating of the protector. 2 same as note 1, except that backup fuse is limited to 80 a maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 vac, 1 pole protector required for : 125 vac, 1? power system. 4 satisfes the requirements of clause 11.2.8.2.5 of csa std c22.2 no 100 for the use of supplementary protectors with portable generators. a-series table a: component supplementary protectors circuit confguration voltage current rating short circuit capacity (amps) application codes construction notes max rating frequency phase full load amps general purpose amps ul / csa with backup fuse without backup fuse ul csa series 32 dc --- 0.02 - 15 --- --- 5000 tc1, ol1, u2 tc1, ol1, u2 65 dc --- 31 - 50 --- --- 7500 tc1, 2, ol1, u1 tc1, 2, ol1, u1 80 dc --- 0.02 - 30 --- --- 7500 tc1, 2, ol1, u1 tc1, 2, ol1, u1 --- 31 - 50 --- 7500 tc1, 2, ol0, u1 tc1, 2, ol0, u1 125 50 / 60 1 0.02 - 30 --- --- 3000 tc1, ol1, u2 tc1, ol1, u2 rocker version 125 50 / 60 1 1 - 50 --- --- 2000 tc1, ol1, u2 tc1, ol1, u2 125 50 / 60 1 4 1 - 50 --- --- 1000 tc1, ol1, u2 tc3, ol1, u3 125 / 250 50 / 60 1 3 0.02 - 30 --- --- 3000 tc1, 2, ol1, u2 tc1, 2, ol1, u2 rocker version 125 / 250 50 / 60 1 3 0.02 - 50 --- --- 3000 tc1, 2, ol1, u2 tc1, 2, ol1, u2 handle 250 50 / 60 1 0.02 - 30 --- --- 1500 tc1, 2, ol0, u2 tc1, 2, ol0, u2 single pole break 0.02 - 30 --- --- 3000 tc1, ol1, u2 tc1, ol1, u2 two pole break --- --- 3000 tc1, 2, ol0, u1 tc1, 2, ol0, u1 1 4 1 - 50 --- --- 1000 tc1, ol1, u2 tc3, ol1, u3 3 0.02 - 30 --- 5000 2 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 31 - 50 --- 2000 1 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 dual coil 32 dc --- 0.02 - 50 --- --- 5000 tc1, ol1, u2 tc1, ol1, u2 65 dc --- 0.02 - 50 --- --- 7500 tc1, 2, ol1, u1 tc1, 2, ol1, u1 80 dc --- 0.02 - 30 --- --- 7500 tc1, 2, ol1, u1 tc1, 2, ol1, u1 --- 31 - 50 --- 7500 tc1, 2, ol0, u1 tc1, 2, ol0, u1 125 50 / 60 1 0.02 - 30 --- --- 3000 tc1, ol1, u2 tc1, ol1, u2 rocker version 1 - 50 --- --- 2000 tc1, ol1, u2 tc1, ol1, u2 125 50 / 60 1 4 0.02 - 30 --- --- 1000 tc1, ol1, u2 tc3, ol1, u3 125 / 250 50 / 60 1 3 0.02 - 30 --- --- 3000 tc1, 2, ol1, u1 tc1, 2, ol1, u1 rocker version 125 / 250 50 / 60 1 3 0.02 - 50 --- --- 3000 tc1, 2, ol1, u2 tc1, 2, ol1, u2 250 50 / 60 1 0.02 - 30 --- --- 1500 tc1, ol0, u2 tc1, ol0, u2 single pole break 1 0.02 - 30 --- --- 3000 tc1, ol1, u2 tc1, ol1, u2 two pole break 1 --- 31 - 50 --- 3000 tc1, 2, ol0, u1 tc1, 2, ol0, u1 1 4 1 - 50 --- --- 1000 tc1, ol1, u2 tc3, ol1, u3 3 0.02 - 30 --- 5000 2 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 31 - 50 --- 2000 1 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- tc1, 2, ol1, u1 tc1, 2, ol1, u1 shunt 80 dc --- 0.02 - 30 --- --- 7500 tc1, 2, ol1, u1 tc1, 2, ol1, u1 125 / 250 50 / 60 1 0.02 - 30 --- --- 3000 tc1, 2, ol1, u1 tc1, 2, ol1, u1 250 50 / 60 1 0.02 - 30 --- --- 3000 tc1, 2, ol1, u1 tc1, 2, ol1, u1 3 0.02 - 30 --- 5000 2 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 relay 80 dc --- 0.02 - 30 --- --- 7500 tc1, 2, ol1, u1 tc1, 2, ol1, u1 125 / 250 50 / 60 1 3 0.02 - 30 --- --- 3000 tc1, 2, ol1, u1 tc1, 2, ol1, u1 250 50 / 60 1 0.02 - 30 --- --- 3000 tc1, 2, ol1, u1 tc1, 2, ol1, u1 3 0.02 - 30 --- 5000 2 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- tc1, 2, ol1, c1 tc1, 2, ol1, c1 switch only 65 dc --- 0.02 - 50 --- not applicable 80 dc --- 0.02 - 30 --- 250 50 / 60 1 --- 31 - 50 3 0.02 - 50 --- 277 50 / 60 1 0.02 - 30 31 - 50
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 4 | a-series circuit breaker - general specifcations 1 2 3 2 3 2 3 electrical tables table b: lists ul recognized, csa accepted, vde & tuv certifed confgurations & performance capabilities as a component supplementary protector. notes: 1 general purpose ratings for ul/csa only. 2 requires branch circuit backup with a ul listed type k5 or rk5 fuse (15a minimum) at no more than 4 times the rating of the protector. 3 same as note 2, except that backup fuse is limited to 80 a maximum. 4 satisfes the requirements of clause 11.2.8.2.5 of csa std c22.2 no 100 for the use of supplementary protectors with portable generators.
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 5 a-series circuit breaker - general specifcations series 14 1 dc --- 0.02 - 50 5000 tc1,ol1,u1 tc1,ol1,u1 32 1 dc --- 0.02 - 50 5000 tc1,ol1,u2 tc1,ol1,u2 65 dc --- 0.02 - 50 3000 tc1,ol1,u1 tc1,ol1,u1 125 50 / 60 1 0.02 - 50 3000 tc1,ol1,u2 tc1,ol1,u2 125 / 250 50 / 60 1 2 0.02 - 50 3000 tc1,ol1,u2 tc1,ol1,u2 250 50 / 60 1 0.02 - 30 1500 tc1,ol1,u1 tc1,ol1,u1 notes: 1 a vailable with special catalog number only (consult factory) 2 2 pole protector required (with one per power line) for 125 / 250 v ac. 1 pole protector required for 125 v ac 1 phase power system csa short circuit cap acity (amps) applica tion codes a-series t able c: ul1500 (marine ignition protected) ul voltage circuit configura tion current ra ting full load amps without backup fuse max. ra ting frequency phase electrical tables table c: lists ul recognized, csa accepted confgurations and performance capabilities as protectors, supplementary for marine electrical and fuel systems (guide peqz2, file e75596). ignition protected per ul 1500. ul classifed small craft electrical devices, marine in accordance with iso 8846 (guide uzmk, file mq1515) as marine supplementary protectors. table d: lists ul listed confgurations and performance capabilities as circuit breakers for use in communications equipment (guide ditt, file e189195), under ul489a. notes: 1 available with special catalog number only (consult factory). 2 2 pole protector required (with one per power line) for 125 / 250 vac. 1 pole protector required for 125 vac 1 phase power system notes: 1 parallel pole construction agency certifications ul recognized ul standard 1077 ul standard 508 ul standard 1500 ul listed ul standard 489a csa accepted tuv certifed vde certifed component recognition program as protectors supplementary (guide ccn/qvnu2, file e75596) switches, industrial control (guide ccn/nrnt2, file e148683) protectors, supplementary for marine electrical & fuel systems (guide peqz2, file e75596) ignition protection communications equipment (guide ccn/ditt, file e189195) component supplementary protector under class 3215 30, file 047848 0 000 csa standard c22.2 no. 235 en60934, under license no. r72103448 en60934, vde 0642 under file no. 10537
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 6 | a-series circuit breaker - handle ul recognized C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 agency approval 4 circuit a a b 1 1 3 0 b c 10 450 1 series a 2 actuator 1 a handle, one per pole b handle, one per multipole unit s mid-trip handle, one per pole t mid-trip handle, one per pole & alarm switch 8 terminal 9 1 10 push-on 0.250 tab (q.c.) e 11 screw m4 (bus type) 2 screw 8-32 with upturned lugs f screw m5 with upturned lugs 3 11 screw 8-32 (bus type) & 30 bend 4 screw 10-32 with upturned lugs g screw m5 (bus type) & 30 bend 5 11 screw 10-32 (bus type) h 11 screw m5 (bus type) 6 screw 8-32 with upturned lugs l 12 0.250 q.c./ solder lug & 30 bend m 11 m6 threaded stud 7 screw 8-32 (bus type) q 14 push-in stud & 30 bend r screw m4 with upturned lugs 8 screw 10-32 with upturned lugs & 30 bend & 30 bend t 11 screw m4 (bus type) 9 screw 10-32 (bus type) & 30 bend & 30 bend p 13 printed circuit board terminals b screw m5 with upturned lugs s 13 push-on 0.110 tab (q.c.) c screw m4 with upturned lugs 10 mounting / barriers mounting style barriers threaded insert, 2 per pole 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches yes 2 iso m3 x 5mm no b iso m3 x 5mm (multipole only) yes front panel snap-in, 0.75 wide bezel 5 without handleguard no 6 without handleguard (multipole only) yes front panel snap-in, 0.96 wide bezel 7 without handleguard, 1-pole 0.96 wide; no multipole units have .105 bezel overhang on all sides 8 without handleguard, 1-pole 0.96 wide; yes (multipole only) .105 bezel overhang on all sides 3 poles 1 one 2 two 3 three 4 four 5 five 6 six 5 auxiliary / alarm switch 5 5 s.p.s.t., 0.093 q.c. term. 0 without aux switch (gold contacts) 1 s.p.d.t., 0.093 q.c. term. 7 s.p.s.t., 0.110 q.c. term. 2 s.p.d.t., 0.110 q.c. term. (gold contacts) 4 s.p.d.t., 0.110 q.c. term. 8 s.p.s.t., 0.187 q.c. term. (gold contacts) 9 s.p.d.t., 0.187 q.c. term. 6 frequency & delay 03 dc 50/60hz, switch only 10 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc, 50/60hz instantaneous 31 dc, 50/60hz ultra short 32 dc, 50/60hz short 34 dc, 50/60hz medium 36 dc, 50/60hz long 42 7 50/60hz short, hi-inrush 44 7 50/60hz medium, hi-inrush 46 7 50/60hz long, hi-inrush 52 7 dc, short,hi-inrush 54 7 dc, medium, hi-inrush 56 7 dc, long, hi-inrush 11 agency approval c ul recognized & csa accepted d vde certifed, ul recognized & csa accepted e tuv certifed, ul recognized & csa accepted i ul recognized std 1077, ul recognized 1500 (ignition protected) , & csa accepted 9 actuator color & legend actuator color i-o on-off dual legend color white a b 1 black black c d 2 white red f g 3 white green h j 4 white blue k l 5 white yellow m n 6 black gray p q 7 black orange r s 8 black black (short handle) 15 t u 9 white 4 circuit a 2 switch only (no coil) f 3 relay trip (current) b series trip (current) g 3 relay trip (voltage) c series trip (voltage) h 3,4 dual coil with shunt trip d 3 shunt trip (current) voltage coil e 3 shunt trip (voltage) k 3,4 dual coil with relay trip voltage coil notes: 1 actuator code: a: handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. b: handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles s: handle moves to mid-position only upon electrical trip of the breaker. available with circuit codes b, c, d, e, f, g, h and k. t: handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. available with circuit codes b & c. 2 switch only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (circuit code b, c, d or h.), for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. 3 available with terminal codes 1, 2 and 3. current rating limited to 50a amps maximum. 4 consult factory for available dual coil options, as special catalog number is required. with shunt construction, dual coils will trip instantaneously on line voltage. dual coils require 30va minimum power to trip and are rated for intermittent duty only. 5 auxiliary switch breakers with series trip & switch only circuits: 30a - supplied with standard half shells. 35-50a - supplied with extended boat (b-style) half shells. on multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 separate pole type voltage coils not rated for continuous duty. available only with delay codes 10 and 20. 7 available with circuit codes b & d only. vde certifed to 30 amps. ul recognized, csa accepted & tuv certifed to 50 amps. 8 vde certifcation available with single pole breakers with dc de lay only. ul recognition and csa accepted available in one and two pole breakers. 9 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9, g, h, m and q.. 10 terminal code 1: vde certifcation up to 25 amps and ul recognition and csa certifcation up to 30 amps, but not recommended over 20 amps. 11 terminal codes 3, 5, e and h (bus type) with vde, are supplied with lock washers, and terminal code m (m6 threaded stud) with vde is supplied with lock and flat washers. these breakers are only vde certifed when the washers are used. 12 terminal code l: vde certifed available up to 12a. ul recognized & csa accepted available up to 30a. 13 single pole breakers with terminal code p (printed circuit board) are available up to 30 amps with vde certifcation and 50 amps with ul recognition and csa accepted, with circuit codes a, b and c. two pole breakers with terminal code p (printed circuit board) are available up to 40 amps with ul recognition and csa accepted with circuit codes a, b and c. 14 terminal code q not available with vde certifcation. 15 single pole only. 7 current rating (amperes) code amperes or voltage coil (normal rated voltage) 6 code amperes a06 6 dc a32 32 dc j12 12 ac j65 65 ac a12 12 dc a48 48 dc j18 18 ac k20 120 ac a18 18 dc a65 65 dc j24 24 ac l40 240 ac a24 24 dc j06 6 ac j48 48 ac 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 7 a-series circuit breaker - handle ul489a C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 max. appl. rating 12 agency approval 4 circuit a a b 1 1 1 0 b m t 14 450 1 series a 2 actuator 1 a handle, one per pole s mid-trip handle, one per pole t mid-trip handle, one per pole & alarm switch 3 poles 2 1 one 2 two 3 three 4 four 5 auxiliary/alarm switch 2 7 s.p.s.t., 0.110 q.c. term. 0 without aux switch (gold contacts) 1 s.p.d.t., 0.093 q.c. term. 8 s.p.s.t., 0.187 q.c. term. 2 s.p.d.t., 0.110 q.c. term. 9 s.p.d.t., 0.187 q.c. term. 6 frequency & delay 11 dc ultra short 12 dc short 14 dc medium 16 dc long 52 3 dc, short,hi-inrush 54 3 dc, medium, hi-inrush 56 3 dc, long, hi-inrush 12 agency approval t ul489a listed k ul489a listed, vde certifed j ul489a listed, tuv certifed 11 maximum application rating m 80 dc 9 actuator color & legend actuator color on-off dual legend color white b 1 black black d 2 white red g 3 white green j 4 white blue l 5 white yellow n 6 black gray q 7 black orange s 8 black black (short handle) 10 u 9 white notes: 1 actuator code: a: handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. s: handle moves to mid-position only upon electrical trip of the breaker. t: handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 on multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 vde certifed to 30 amps. ul489a listed to 50 amps. 4 vde certifcation available with single pole breakers only. ul489a listing available with one and two pole breakers. 5 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9 g, h, m and q. 6 terminal code 1 (push-on) available up to 25 amps with vde certifcation and 30 amps with ul489a listing, but is not recommended over 20 amps. 7 terminal codes 3, 5 and h (bus type) with vde, are supplied with lock washers, and terminal code m (m6 threaded stud) with vde is supplied with lock and flat washers. these breakers are only vde certifed when the washers are used. 8 single pole breakers with terminal code p (printed circuit board) are available up to 30 amps with vde certifcation and 50 amps with ul489a listing. 9 terminal code q not available with vde certifcation. 10 single pole only. 4 circuit b series trip (current) 8 terminal 5 1 6 push-on 0.250 tab (q.c.) 9 screw 10-32 (bus type) 2 screw 8-32 with upturned lugs & 30 bend 3 7 screw 8-32 (bus type) b screw m5 with upturned lugs 4 screw 10-32 with upturned lugs f screw m5 with upturned lugs 5 7 screw 10-32 (bus type) & 30 bend 6 screw 8-32 with upturned lugs g screw m5 (bus type) & 30 bend & 30 bend h screw m5 (bus type) 7 screw 8-32 (bus type) m 7 m6 threaded stud & 30 bend p 8 printed circuit board terminals 8 screw 10-32 with upturned lugs q 9 push-in stud & 30 bend 10 mounting / barriers mounting style barriers threaded insert, 2 per pole 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches yes 2 iso m3 x 5mm no b iso m3 x 5mm (multipole only) yes front panel snap-in, 0.75 wide bezel 5 without handleguard no 6 without handleguard (multipole only) yes front panel snap-in, 0.96 wide bezel 7 without handleguard, 1-pole 0.96 wide; no multipole units have .105 bezel overhang on all sides 8 without handleguard, 1-pole 0.96 wide; yes (multipole only) .105 bezel overhang on all sides 7 current rating (amperes) code amperes 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 3 35.000 640 3 40.000 645 3 45.000 650 3 50.000
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 8 | a-series circuit breaker - handle world C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 agency approval 4 circuit a a b 1 1 3 0 a p 14 450 1 series a 2 actuator 1 a handle, one per pole b handle, one per multipole unit s mid-trip handle, one per pole t mid-trip handle, one per pole & alarm switch 8 terminal 9 1 10 push-on 0.250 tab (q.c.) b screw m5 with upturned lugs 2 screw 8-32 with upturned lugs c screw m4 with upturned lugs 3 11 screw 8-32 (bus type) e 11 screw m4 (bus type) 4 screw 10-32 with upturned lugs f screw m5 with upturned lugs 5 11 screw 10-32 (bus type) & 30 bend 6 screw 8-32 with upturned lugs g screw m5 (bus type) & 30 bend & 30 bend h 11 screw m5 (bus type) 7 screw 8-32 (bus type) r screw m4 with upturned lugs & 30 bend & 30 bend 8 screw 10-32 with upturned lugs t 11 screw m4 (bus type) & 30 bend & 30 bend 9 screw 10-32 (bus type) & 30 bend 10 mounting / barriers mounting style barriers threaded insert, 2 per pole 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches yes 2 iso m3 x 5mm no b iso m3 x 5mm (multipole only) yes front panel snap-in, 0.75 wide bezel 5 without handleguard no 6 without handleguard (multipole only) yes front panel snap-in, 0.96 wide bezel 7 without handleguard, 1-pole 0.96 wide; no multipole units have .105 bezel overhang on all sides 8 without handleguard, 1-pole 0.96 wide; yes (multipole only) .105 bezel overhang on all sides 3 poles 1 one 2 two 3 three 4 four 5 five 6 six 5 auxiliary / alarm switch 5 0 without aux switch 2 s.p.d.t., 0.110 q.c. term. 4 s.p.d.t., 0.110 q.c. term. (gold contacts) 6 frequency & delay 03 dc 50/60hz, switch only 10 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc, 50/60hz instantaneous 31 dc, 50/60hz ultra short 32 dc, 50/60hz short 34 dc, 50/60hz medium 36 dc, 50/60hz long 42 7 50/60hz short, hi-inrush 44 7 50/60hz medium, hi-inrush 46 7 50/60hz long, hi-inrush 52 7 dc, short,hi-inrush 54 7 dc, medium, hi-inrush 56 7 dc, long, hi-inrush 11 agency approval p tuv certifed, ul recognized & csa accepted q ul recognized std 1077, ul recognized 1500 (ignition protected) , & csa accepted 9 actuator color & legend actuator color i-o dual legend color white a 1 black black c 2 white red f 3 white green h 4 white blue k 5 white yellow m 6 black gray p 7 black orange r 8 black black (short handle) 15 t 9 white 4 circuit a 2 switch only (no coil) d 3 shunt trip (current) b series trip (current) e 3 shunt trip (voltage) c series trip (voltage) h 3,4 dual coil with shunt trip voltage coil notes: 1 actuator code: a: handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. s: handle moves to mid-position only upon electrical trip of the breaker. available with circuit codes b, c, d, e, and h. t: handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. available with circuit codes b & c. 2 switch only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (circuit code b, c, d or h.), for .01 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. 3 available with terminal codes 1, 2 and 3. current rating limited to 30 amps maximum. 4 consult factory for available dual coil options, as special catalog number is required. with shunt construction, dual coils will trip instantaneously on line voltage. dual coils require 30va minimum power to trip and are rated for intermittent duty only. 5 on multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 separate pole type voltage coils not rated for continuous duty. available only with delay codes 10, 20 & 30. 7 available with circuit codes b & d only. vde certifed to 30 amps. ul recognized, csa accepted & tuv certifed to 50 amps. 8 available up to two poles with ac or dc delays. 9 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9, g and h. 10 terminal code 1: tuv certifcation up to 30 amps, but not recommended over 20 amps. 11 terminal codes 3, 5 , 7, 9, e, g and h (bus type) are supplied with lock washers. these breakers are only tuv certifed when the washers are used. 12 single pole only. 7 current rating (amperes) code amperes or voltage coil (normal rated voltage) 6 code amperes a06 6 dc a32 32 dc j12 12 ac j65 65 ac a12 12 dc a48 48 dc j18 18 ac k20 120 ac a18 18 dc a65 65 dc j24 24 ac l40 240 ac a24 24 dc j06 6 ac j48 48 ac 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 9 a-series circuit breaker - rocker ul489a C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 max. appl. rating 12 agency approval 4 circuit a f b 1 1 1 0 3 m t 14 450 1 series a 10 mounting / barriers 11 standard rocker bezel barriers threaded insert, 2 per pole 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches (multi-pole units only) yes 2 iso m3 x 5mm no b iso m3 x 5mm (multi-pole units only) yes rockerguard & push-to-reset bezel threaded insert, 2 per pole 3 6-32 x 0.195 inches no c 6-32 x 0.195 inches (multi-pole units only) yes 4 iso m3 x 5mm no d iso m3 x 5mm (multi-pole units only) yes front panel snap-in bracket, 0.744 [18.90mm] wide bezel 8 without rockerguard (single pole units only) no h with rockerguard (single pole units only) no front panel snap-in bracket, 0.96 [24.48mm] wide bezel 9 without rockerguard (single pole units only) no j with rockerguard (single pole units only) no notes: 1 push-to-reset actuators have off portion of rocker shrouded. 2 multi-pole breakers have all breakers identical except when specifying auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 auxiliary switch breakers with series trip circuits: 30a, are supplied with standard half shells. 30-50a are supplied with extended boat (b-style) half shells. 4 vde certifcation available with single pole breakers only. ul489a listing available with one and two pole breakers. 5 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9, g, h, m and q. 6 terminal code 1 (push-on) available up to 25 amps with tuv or vde certifcation and 30 amps with ul489a listing, but is not recommended over 20 amps. 7 terminal codes 3, 5 and h (bus type) with tuv or vde, are supplied with lock washers, and terminal code m (m6 threaded stud) with vde is supplied with lock and flat washers. these breakers are only tuv or vde certifed when the washers are used. 8 single pole breakers with terminal code p (printed circuit board) are available up to 30 amps with vde certifcation and 50 amps with ul489a listing. 9 terminal code q not available with vde certifcation. 10 color shown is visi and legend with remainder of rocker black. dual = on-off/i-o legend. 11 legend on push-to-reset bezel/shroud is white with single color actuator codes r & u. legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes n & o. rockerguard available with actuator codes c through k 2 actuator 1 two color visi-rocker push-to-reset, visi-rocker c indicate on, vertical legend n indicate off, vertical legend d indicate on, horizontal legend o indicate off, horizontal legend f indicate off, vertical legend g indicate off, horizontal legend single color push-to-reset , single color j vertical legend r vertical legend k horizontal legend u horizontal legend 9 actuator color & legend actuator or marking: marking color visi-color 10 on-off dual 10 single color visi-rocker white b 1 black white black d 2 white n/a red g 3 white red green j 4 white green blue l 5 white blue yellow n 6 black yellow gray q 7 black gray orange s 8 black orange 3 poles 2 1 one 2 two 3 three 5 auxiliary / alarm switch 2 7 s.p.s.t., 0.110 q.c. term. 0 without aux switch (gold contacts) 1 s.p.d.t., 0.093 q.c. term. 8 s.p.s.t., 0.187 q.c. term. 2 s.p.d.t., 0.110 q.c. term. 9 s.p.d.t., 0.187 q.c. term. 6 frequency & delay 11 dc ultra short 12 dc short 14 dc medium 16 dc long 52 dc, short,hi-inrush 54 dc, medium, hi-inrush 56 dc, long, hi-inrush 12 agency approval t ul489a listed k ul489a listed, vde certifed j ul489a listed, tuv certifed 11 maximum application rating m 80 dc 4 circuit b series trip (current) 8 terminal 5 1 6 push-on 0.250 tab (q.c.) 9 screw 10-32 (bus type) 2 screw 8-32 with upturned lugs & 30 bend 3 7 screw 8-32 (bus type) b screw m5 with upturned lugs 4 screw 10-32 with upturned lugs f screw m5 with upturned lugs 5 7 screw 10-32 (bus type) & 30 bend 6 screw 8-32 with upturned lugs g screw m5 (bus type) & 30 bend & 30 bend h screw m5 (bus type) 7 screw 8-32 (bus type) m 7 m6 threaded stud & 30 bend p 8 printed circuit board terminals 8 screw 10-32 with upturned lugs q 9 push-in stud & 30 bend 7 current rating (amperes) code amperes 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 4 35.000 640 4 40.000 645 4 45.000 650 4 50.000
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 10 | a-series circuit breaker - handle C circuit & terminal diagrams notes: 1 all dimensions are in inches [millimeters]. 2 tolerance .020 [.51] unless otherwise specifed. 3 alarm switch available with .110 x .020 q.c. & solder lug terminals only. circuit & terminal diagrams: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 11 a-series circuit breaker - handle C circuit & terminal diagrams notes: 1 all dimensions are in inches [millimeters]. 2 tolerance .020 [.51] unless otherwise specifed. 3 alarm switch available with .110 x .020 qc & solder lug terminals only. circuit & terminal diagrams: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 12 | a-series circuit breaker - handle - dimensional specifcations notes: 1 all dimensions are in inches [millimeters]. 2 tolerance 0.20 [.51] unless otherwise specifed. 3 for agency code p = .150 [3.81]. dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 13 a-series circuit breaker - handle C front panel snap-in mounting style 5 - dimensional specifcations notes: 1 all dimensions are in inches [millimeters]. 2 recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 tolerance .020 [.51] unless otherwise specifed. dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 14 | a-series circuit breaker - handle C front panel snap-in mounting style 7 - dimensional specifcations notes: 1 all dimensions are in inches [millimeters]. 2 recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 tolerance .020 [.51] unless otherwise specifed. dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 15 a-series circuit breaker - sealed toggle ul recognized C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 agency approval 4 circuit a m b 1 1 1 0 0 c 10 450 1 series a 2 actuator 1 m sealed toggle, one per unit 10 mounting / barriers mounting style barriers 1 standard hex nut no a standard hex nut (multipole only) yes 3 poles 1 one 2 two 3 three 9 legend plate 0 no legend plate notes: 1 actuator code m: handle location as viewed from front of panel: 2 pole - right pole 3 pole - center pole 2 switch only circuits, rated up to 50 amps and 3 poles. only available when tied to a protected pole. for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. 3 available with terminal codes 1, 2 and 3. current rating limited to 30 amps maximum. 4 consult factory for available dual coil options, as special catalog number is required. with shunt construction, dual coils will trip instantaneously on line voltage. dual coils require 30va minimum power to trip and are rated for intermittent duty only. 5 auxiliary switch available on series trip & switch only circuits, limited to 30 amps. on multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 voltage coils not rated for continuous duty. available only with delay codes 10 and 20. 7 available with circuit codes b & d only. vde certifed to 30 amps. ul recognized, csa accepted & tuv certifed to 50 amps. 8 ul recognition and csa certifcation available on one and two pole breakers. 9 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9, b, f, g, h, m and q. 10 terminal code 1: ul recognition and csa certifcation up to 30 amps, but not recommended over 20 amps. 11 terminal code l : available up to 30a. 12 single pole breakers with terminal code p (printed circuit board) are available up to 50 amps, with circuit codes a, b and c. two pole breakers with terminal code p (printed circuit board) are available up to 40 amps with circuit codes a, b and c. 8 terminal 9 1 10 push-on 0.250 tab (q.c.) e screw m4 (bus type) 2 screw 8-32 with upturned lugs f screw m5 with upturned lugs 3 screw 8-32 (bus type) & 30 bend 4 screw 10-32 with upturned lugs g screw m5 (bus type) & 30 bend 5 screw 10-32 (bus type) h screw m5 (bus type) 6 screw 8-32 with upturned lugs l 12 0.250 q.c./ solder lug & 30 bend m m6 threaded stud 7 screw 8-32 (bus type) q push-in stud & 30 bend r screw m4 with upturned lugs 8 screw 10-32 with upturned lugs & 30 bend & 30 bend t screw m4 (bus type) 9 screw 10-32 (bus type) & 30 bend & 30 bend p 12 printed circuit board terminals b screw m5 with upturned lugs s push-on 0.110 tab (q.c.) c screw m4 with upturned lugs 5 auxiliary / alarm switch 5 5 s.p.s.t., 0.093 q.c. term. 0 without aux switch (gold contacts) 1 s.p.d.t., 0.093 q.c. term. 7 s.p.s.t., 0.110 q.c. term. 2 s.p.d.t., 0.110 q.c. term. (gold contacts) 4 s.p.d.t., 0.110 q.c. term. 8 s.p.s.t., 0.187 q.c. term. (gold contacts) 9 s.p.d.t., 0.187 q.c. term. 6 frequency & delay 03 dc 50/60hz, switch only 10 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc, 50/60hz instantaneous 31 dc, 50/60hz ultra short 32 dc, 50/60hz short 34 dc, 50/60hz medium 36 dc, 50/60hz long 42 7 50/60hz short, hi-inrush 44 7 50/60hz medium, hi-inrush 46 7 50/60hz long, hi-inrush 52 7 dc, short,hi-inrush 54 7 dc, medium, hi-inrush 56 7 dc, long, hi-inrush 11 agency approval c ul recognized & csa accepted i ul recognized std 1077, ul recognized 1500 (ignition protected) , & csa accepted 4 circuit a 2 switch only (no coil) f 3 relay trip (current) b series trip (current) g 3 relay trip (voltage) c series trip (voltage) h 3,4 dual coil with shunt trip d 3 shunt trip (current) voltage coil e 3 shunt trip (voltage) k 3,4 dual coil with relay trip voltage coil 7 current rating (amperes) code amperes or voltage coil (normal rated voltage) 6 code amperes a06 6 dc a32 32 dc j12 12 ac j65 65 ac a12 12 dc a48 48 dc j18 18 ac k20 120 ac a18 18 dc a65 65 dc j24 24 ac l40 240 ac a24 24 dc j06 6 ac j48 48 ac 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 16 | a-series circuit breaker - sealed toggle - dimensional specifcations notes: 1 all dimensions are in inches [millimeters]. 2 tolerance .020 [.51] unless otherwise specifed. dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 17 a-series circuit breaker - rocker ul recognized C ordering scheme 2 actuator 1 two color visi-rocker c indicate on, vertical legend d indicate on, horizontal legend f indicate off, vertical legend g indicate off, horizontal legend h indicate off, no legend push-to-reset, visi-rocker n indicate off, vertical legend o indicate off, horizontal legend p indicate off, no legend single color j vertical legend k horizontal legend l no legend push-to-reset , single color r vertical legend u horizontal legend v no legend 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 agency approval 4 circuit a f b 2 1 1 0 3 d 24 630 1 series a 3 poles 1 one 2 two 3 three 11 agency approval c ul recognized & csa accepted d vde certifed, ul recognized & csa accepted e tuv certifed, ul recognized & csa accepted i ul recognized std 1077, ul recognized 1500 (ignition protected) , & csa accepted notes: 1 push-to-reset actuators have off portion of rocker shrouded. 2 multi-pole breakers have all breakers identical except when specifying auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 switch only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole (circuit code b, c, d or h.), for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. 4 available with terminal codes 1, 2 and 3. current rating limited to 30 amps maximum. 5 consult factory for dual coil options, as special catalog number is required. with shunt construction, dual coils will trip instantaneously on line voltage. dual coils require 30va minimum power to trip and are rated for intermittent duty only. 6 auxiliary switch breakers with series trip & switch only circuits: 30a, are supplied with standard half shells. 30-50a are supplied with extended boat (b-style) half shells. 7 on multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 8 separate pole type voltage coils not rated for continuous duty. available only with delay codes 10 & 20. 9 available with circuit codes b & d only. vde certifed to 30 amps. ul recognized, csa accepted & tuv certifed to 50 amps. 10 series trip current ratings: vde certifcation available with single pole breakers with dc delay only. ul recognition & csa accepted available in one and two pole breakers. 11 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9, g, h, m and q. 12 terminal code 1: vde certifcation up to 25 amps and ul recognition and csa accepted up to 30 amps, but not recommended over 20 amps. 13 terminal codes 3, 5 e & h (bus type) with vde, are supplied with lock washers; terminal code m (m6 threaded stud) with vde is supplied with lock and flat washers. these breakers are only vde certifed when the washers are used. 14 vde cert. available up to 12 amps. ul rec. & csa accepted available up to 30 amps. 15 single pole breakers with terminal code p (printed circuit board) are available up to 30 amps with vde certifcation and 50 amps with ul recognition and csa accepted, with circuit codes a, b & c. two pole breakers with terminal code p (printed circuit board) are available up to 40 amps with ul recognition and csa certifcation with circuit codes a, b and c. 16 terminal code q not available with vde. 17 terminal code s used on voltage coil circuit constructions only. 18 color shown is visi and legend with remainder of rocker black. 19 dual = on-off/i-o legend with actuator. none = no legend on actuator 20 legend on push-to-reset bezel/shroud is white with single color actuator codes r, & u. legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes n & o. rockerguard available with actuator codes c through l. 8 terminal 11 1 12 push-on 0.250 tab (q.c.) e 13 screw m4 (bus type) 2 screw 8-32 with upturned lugs f screw m5 with upturned lugs 3 13 screw 8-32 (bus type) & 30 bend 4 screw 10-32 with upturned lugs g screw m5 (bus type) & 30 bend 5 13 screw 10-32 (bus type) h 13 screw m5 (bus type) 6 screw 8-32 with upturned lugs l 14 0.250 q.c./ solder lug & 30 bend m 13 m6 threaded stud 7 screw 8-32 (bus type) p 15 printed circuit board terminals & 30 bend q 16 push-in stud 8 screw 10-32 with upturned lugs r screw m4 with upturned lugs & 30 bend & 30 bend 9 screw 10-32 (bus type) s 17 push-on 0.110 tab (q.c.) & 30 bend & 30 bend b screw m5 with upturned lugs t screw m4 (bus type) c screw m4 with upturned lugs & 30 bend 5 auxiliary / alarm switch 6,7 5 s.p.s.t., 0.093 q.c. term. 0 without aux switch (gold contacts) 1 s.p.d.t., 0.093 q.c. term. 7 s.p.s.t., 0.110 q.c. term. 2 s.p.d.t., 0.110 q.c. term. (gold contacts) 4 s.p.d.t., 0.110 q.c. term. 8 s.p.s.t., 0.187 q.c. term. (gold contacts) 9 s.p.d.t., 0.187 q.c. term. 6 frequency & delay 03 dc 50/60hz, switch only 10 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc, 50/60hz instantaneous 31 dc, 50/60hz ultra short 32 dc, 50/60hz short 34 dc, 50/60hz medium 36 dc, 50/60hz long 42 9 50/60hz short, hi-inrush 44 9 50/60hz medium, hi-inrush 46 9 50/60hz long, hi-inrush 52 9 dc, short,hi-inrush 54 9 dc, medium, hi-inrush 56 9 dc, long, hi-inrush 4 circuit f 4 relay trip (current) a 3 switch only (no coil) g 4 relay trip (voltage) b series trip (current) h 4,5 dual coil with shunt trip c series trip (voltage) voltage coil d 4 shunt trip (current) k 4,5 dual coil with relay trip e 4 shunt trip (voltage) voltage coil 7 current rating (amperes) code amperes or voltage coil (normal rated voltage) 8 code amperes a06 6 dc a32 32 dc j12 12 ac j65 65 ac a12 12 dc a48 48 dc j18 18 ac k20 120 ac a18 18 dc a65 65 dc j24 24 ac l40 240 ac a24 24 dc j06 6 ac j48 48 ac 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000 10 mounting / barriers 20 standard rocker bezel barriers threaded insert, 2 per pole 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches (multi-pole units only) yes 2 iso m3 x 5mm no b iso m3 x 5mm (multi-pole units only) yes rockerguard & push-to-reset bezel threaded insert, 2 per pole 3 6-32 x 0.195 inches no c 6-32 x 0.195 inches (multi-pole units only) yes 4 iso m3 x 5mm no d iso m3 x 5mm (multi-pole units only) yes front panel snap-in bracket, 0.744 [18.90mm] wide bezel 8 without rockerguard (single pole units only) no h with rockerguard (single pole units only) no front panel snap-in bracket, 0.96 [24.48mm] wide bezel 9 without rockerguard (single pole units only) no j with rockerguard (single pole units only) no 9 actuator color & legend actuator or marking: marking color visi-color 12 on-off dual 12 single color visi-rocker white b 1 black white black d 2 white n/a red g 3 white red green j 4 white green blue l 5 white blue yellow n 6 black yellow gray q 7 black gray orange s 8 black orange
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 18 | a-series circuit breaker - flat rocker ul recognized C ordering scheme 3 poles 2 1 one 2 two 3 three 11 agency approval c ul recognized & csa accepted e tuv certifed, ul recognized & csa accepted i ul recognized std 1077, ul recognized 1500 (ignition protected) , & csa accepted 1 series a 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 agency approval 4 circuit a 1 b 2 1 1 0 3 e 24 630 2 actuator 1 two color visi-rocker 1 indicate off, vertical legend 2 indicate off, horizontal legend single color 3 vertical legend 4 horizontal legend push-to-reset, visi-rocker 5 indicate off, vertical legend 6 indicate off, horizontal legend push-to-reset , single color 7 vertical legend 8 horizontal legend 10 mounting / barriers 18 standard rocker bezel barriers threaded insert, 2 per pole flat rocker actuator 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches (multi-pole units only) yes 2 iso m3 x 5mm no b iso m3 x 5mm (multi-pole units only) yes recessed off side rocker actuator 19 5 6-32 x 0.195 inches no e 6-32 x 0.195 inches (multi-pole units only) yes 6 iso m3 x 5mm no f iso m3 x 5mm (multi-pole units only) yes push-to-reset bezel,threaded insert, 2 per pole 3 6-32 x 0.195 inches no c 6-32 x 0.195 inches (multi-pole units only) yes 4 iso m3 x 5mm no d iso m3 x 5mm (multi-pole units only) yes notes: 1 push-to-reset actuators have off portion of rocker shrouded. 2 multi-pole breakers have all breakers identical except when specifying auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 switch only circuits, rated up to 50 amps & 3 poles. only available when tied to a protected pole. for .02 to 30 amps, select current code 630. for 35 - 50 amps, select current code 650. 4 available with terminal codes 1, 2 and 3. current rating limited to 30 amps maximum. 5 consult factory for dual coil options, as special catalog number is required. with shunt construction, dual coils will trip instantaneously on line voltage. dual coils require 30va minimum power to trip and are rated for intermittent duty only. 6 auxiliary switch breakers with series trip & switch only circuits: 30a, are supplied with standard half shells. 30-50a are supplied with extended boat (b-style) half shells. 7 on multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 8 separate pole type voltage coils not rated for continuous duty. available only with delay codes 10 & 20. 9 available with circuit codes b & d only. ul recognized, csa accepted & tuv certifed to 50 amps. 10 ul recognition, csa acceptance & tuv certifcation available in one and two pole breakers. 11 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9, g, h, m and q. 12 terminal code 1: available up to 30 amps, but not recommended over 20 amps. 13 terminal codes 3, 5 e & h (bus type) with tuv, are supplied with lock washers; terminal code m (m6 threaded stud) with tuv is supplied with lock and flat washers. these breakers are only tuv certifed when the washers are used. 14 tuv cert. available up to 12 amps. ul rec. & csa accepted available up to 30 amps. 15 single pole breakers with terminal code p (printed circuit board) are available up to 50 amps with ul recognition, csa accepted & tuv certifcation, with circuit codes a, b and c. two pole breakers with terminal code p (printed circuit board) are available up to 40 amps with ul recognition and csa accepted with circuit codes a, b and c. 16 terminal code s used on voltage coil circuit constructions only. 17 color shown is visi and legend with remainder of rocker black, dual = on-off/i-o legend. 18 legend on push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. 19 recessed off-side available with actuator codes 1, 2, 3 & 4. legends on rocker are available in ink stamping only. 8 terminal 11 1 12 push-on 0.250 tab (q.c.) e 13 screw m4 (bus type) 2 screw 8-32 with upturned lugs f screw m5 with upturned lugs 3 13 screw 8-32 (bus type) & 30 bend 4 screw 10-32 with upturned lugs g screw m5 (bus type) & 30 bend 5 13 screw 10-32 (bus type) h 13 screw m5 (bus type) 6 screw 8-32 with upturned lugs l 14 0.250 q.c./ solder lug & 30 bend m 13 m6 threaded stud 7 screw 8-32 (bus type) p 15 printed circuit board terminals & 30 bend q push-in stud 8 screw 10-32 with upturned lugs r screw m4 with upturned lugs & 30 bend & 30 bend 9 screw 10-32 (bus type) s 16 push-on 0.110 tab (q.c.) & 30 bend & 30 bend b screw m5 with upturned lugs t screw m4 (bus type) c screw m4 with upturned lugs & 30 bend 5 auxiliary / alarm switch 6,7 5 s.p.s.t., 0.093 q.c. term. 0 without aux switch (gold contacts) 1 s.p.d.t., 0.093 q.c. term. 7 s.p.s.t., 0.110 q.c. term. 2 s.p.d.t., 0.110 q.c. term. (gold contacts) 4 s.p.d.t., 0.110 q.c. term. 8 s.p.s.t., 0.187 q.c. term. (gold contacts) 9 s.p.d.t., 0.187 q.c. term. 6 frequency & delay 03 dc 50/60hz, switch only 10 6 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 6 50/60hz instantaneous 21 50/60hz ultra short 22 50/60hz short 24 50/60hz medium 26 50/60hz long 30 dc, 50/60hz instantaneous 31 dc, 50/60hz ultra short 32 dc, 50/60hz short 34 dc, 50/60hz medium 36 dc, 50/60hz long 42 9 50/60hz short, hi-inrush 44 9 50/60hz medium, hi-inrush 46 9 50/60hz long, hi-inrush 52 9 dc, short,hi-inrush 54 9 dc, medium, hi-inrush 56 dc, long, hi-inrush 4 circuit f 4 relay trip (current) a 3 switch only (no coil) g 4 relay trip (voltage) b series trip (current) h 4,5 dual coil with shunt trip c series trip (voltage) voltage coil d 4 shunt trip (current) k 4,5 dual coil with relay trip e 4 shunt trip (voltage) voltage coil 7 current rating (amperes) code amperes or voltage coil (normal rated voltage) 8 code amperes a06 6 dc a32 32 dc j12 12 ac j65 65 ac a12 12 dc a48 48 dc j18 18 ac k20 120 ac a18 18 dc a65 65 dc j24 24 ac l40 240 ac a24 24 dc j06 6 ac j48 48 ac 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000 9 actuator color & legend actuator or marking: marking color visi-color 17 on-off dual 17 single color visi-rocker white b 1 black white black d 2 white n/a red g 3 white red green j 4 white green blue l 5 white blue yellow n 6 black yellow gray q 7 black gray orange s 8 black orange
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 19 a-series circuit breaker - flat rocker ul 489a C ordering scheme 1 series 2 actuator 3 poles 5 aux/alarm switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 max. appl. rating 12 agency approval 4 circuit a 1 b 2 1 1 0 3 m t 14 630 1 series a 12 agency approval t ul489a listed j ul489a listed, tuv certifed 11 maximum application rating m 80 dc notes: 1 push-to-reset actuators have off portion of rocker shrouded. 2 multi-pole breakers have all breakers identical except when specifying auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 auxiliary switch breakers with series trip circuits: 30a, are supplied with standard half shells. 30-50a are supplied with extended boat (b-style) half shells. 4 vde certifcation available with single pole breakers only. ul489a listing available with one and two pole breakers. 5 screw terminals are recommended on ratings greater than 20 amps. ratings over 30 amps are only available with terminal codes 5, 9, g, h, m and q. 6 terminal code 1 (push-on) available up to 25 amps with tuv or vde certifcation and 30 amps with ul489a listing, but is not recommended over 20 amps. 7 terminal codes 3, 5 and h (bus type) with tuv or vde, are supplied with lock washers, and terminal code m (m6 threaded stud) with vde is supplied with lock and flat washers. these breakers are only tuv or vde certifed when the washers are used. 8 single pole breakers with terminal code p (printed circuit board) are available up to 30 amps with vde certifcation and 50 amps with ul489a listing. 9 terminal code q not available with vde certifcation. 10 color shown is visi and legend with remainder of rocker black. dual = on-off/i-o legend. 11 legend on push-to-reset bezel/shroud is white with single color actuator codes r & u. 12 legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes n & o. rockerguard available with actuator codes c through k 3 poles 2 1 one 2 two 3 three 2 actuator 1 two color visi-rocker 1 indicate off, vertical legend 2 indicate off, horizontal legend single color 3 vertical legend 4 horizontal legend push-to-reset, visi-rocker 5 indicate off, vertical legend 6 indicate off, horizontal legend push-to-reset , single color 7 vertical legend 8 horizontal legend 10 mounting / barriers 12 standard rocker bezel barriers threaded insert, 2 per pole flat rocker actuator 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches (multi-pole units only) yes 2 iso m3 x 5mm no b iso m3 x 5mm (multi-pole units only) yes recessed off side rocker actuator 5 6-32 x 0.195 inches no e 6-32 x 0.195 inches (multi-pole units only) yes 6 iso m3 x 5mm no f iso m3 x 5mm (multi-pole units only) yes push-to-reset bezel,threaded insert, 2 per pole 3 6-32 x 0.195 inches no c 6-32 x 0.195 inches (multi-pole units only) yes 4 iso m3 x 5mm no d iso m3 x 5mm (multi-pole units only) yes 5 auxiliary / alarm switch 3 7 s.p.s.t., 0.110 q.c. term. 0 without aux switch (gold contacts) 1 s.p.d.t., 0.093 q.c. term. 8 s.p.s.t., 0.187 q.c. term. 2 s.p.d.t., 0.110 q.c. term. 9 s.p.d.t., 0.187 q.c. term. 6 frequency & delay 11 dc ultra short 12 dc short 14 dc medium 16 dc long 52 dc, short,hi-inrush 54 dc, medium, hi-inrush 56 dc, long, hi-inrush 4 circuit b series trip (current) 7 current rating (amperes) code amperes 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 4 35.000 640 4 40.000 645 4 45.000 650 4 50.000 9 actuator color & legend actuator or marking: marking color visi-color 11 on-off dual 11 single color visi-rocker white b 1 black white black d 2 white n/a red g 3 white red green j 4 white green blue l 5 white blue yellow n 6 black yellow gray q 7 black gray orange s 8 black orange 8 terminal 5 1 6 push-on 0.250 tab (q.c.) 9 screw 10-32 (bus type) 2 screw 8-32 with upturned lugs & 30 bend 3 7 screw 8-32 (bus type) b screw m5 with upturned lugs 4 screw 10-32 with upturned lugs f screw m5 with upturned lugs 5 7 screw 10-32 (bus type) & 30 bend 6 screw 8-32 with upturned lugs g screw m5 (bus type) & 30 bend & 30 bend h screw m5 (bus type) 7 screw 8-32 (bus type) m 7 m6 threaded stud & 30 bend p 8 printed circuit board terminals 8 screw 10-32 with upturned lugs q 9 push-in stud & 30 bend
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 20 | a-series circuit breaker - recessed paddle C ordering scheme 1 series 2 actuator 3 poles 5 auxiliary switch 6 frequency & delay 7 current rating 8 terminal 9 actuator color 10 mounting/ barriers 11 max. appl. rating 12 agency approval 4 circuit a y b 4 1 2 0 2 c c 24 620 1 series a 12 agency approval 7 a without approvals c ul recognized and csa accepted t ul 489a 11 maximum application rating 6 a 65 vdc c 120/240 vac (available only on 2 or 3-pole units) k 120 vac m 80 dc notes: 1 all standard catalog numbers are supplied with vertical legends. for horizontal or other non-standard legends, choose x and order as a special catalog number. 2 for rating (t) 2 & 3 pole not available. 3 frequency and time delay ratings of (03, 20, 21, 22, 24, 26, 42, 44, 46) not available with approval t. 4 voltage coil ratings starting with (j, k, or l) not available with approval t. 5 off and/or o legends are on bracket and are only visible when the paddle actuator is in the off position. 6 maximum application ratings (c & k) not available with approval t. 7 not all approvals are available in all constructions. consult factory for details. 3 poles 2 1 one 2 two 3 three 2 actuator 1 y single color recessed paddle actuator with vertical legends 10 mounting / barriers barriers 1 6-32 x 0.195 inches no a 6-32 x 0.195 inches (multi-pole units only) yes 2 iso m3 x 5mm no b iso m3 x 5mm (multi-pole units only) yes 5 auxiliary switch 0 without aux switch 1 s.p.d.t. with 0.093 q.c. terminals 2 s.p.d.t. with 0.110 q.c. terminals 3 s.p.d.t. with 0.139 solder lug terminals 4 s.p.d.t. with 0.110 q.c. terminals (gold contacts) 5 s.p.d.t. with 0.093 q.c. terminals (gold contacts) 6 s.p.s.t.-n.o. with 0.139 solder lug terminals 7 s.p.s.t.-n.o. with 0.110 q.c. terminals (gold contacts) 8 s.p.s.t.-n.o. with 0.187 q.c. terminals 9 s.p.d.t. with 0.187 q.c. terminals 6 frequency & delay 3 3 dc, 50/60 hz switch only 10 dc instantaneous 11 dc ultra short 12 dc short 14 dc medium 16 dc long 20 50/60 hz instantaneous 21 50/60 hz ultra short 22 50/60 hz short 24 50/60 hz medium 26 50/60 hz long 42 50/60 hz short hi-inrush 44 50/60 hz medium hi-inrush 46 50/60 hz long hi-inrush 52 dc, short, hi-inrush 54 dc, medium, hi-inrush 56 dc, long, hi-inrush 4 circuit a switch-only (no coil) f relay trip (current) b series trip (current) g relay trip (voltage) c series trip (voltage) h dual coil with shunt trip voltage coil d shunt trip (current) k dual coil with shunt trip current coil e shunt trip (voltage) 8 terminal 1 push-on 0.250 tab (q.c.) c screw, m4 with upturned lugs 2 screw 8-32 with upturned lugs e screw, m4 (bus type) 3 screw 8-32 (bus type) f screw m5 with upturned lugs 4 screw 10-32 with upturned lugs & 30 bend 5 screw 10-32 (bus type) g screw m5 (bus type) & 30 bend 6 screw 8-32 with upturned lugs h screw m5 (bus type) & 30 bend l 0.250 q.c./solder lug 7 screw 8-32 (bus type) m m6 threaded stud & 30 bend p printed circuit board terminals 8 screw 10-32 with upturned lugs q push-in stud & 30 bend r screw, m4 with upturned lugs 9 screw 10-32 (bus type) & 30 bend & 30 bend s screw, m5 with upturned lugs b screw m5 with upturned lugs t screw, m4 with upturned lugs 7 current rating (amperes) 4 code amperes or voltage coil (normal rated voltage) code amperes a06 6 dc a32 32 dc j12 12 ac j65 65 ac a12 12 dc a48 48 dc j18 18 ac k20 120 ac a18 18 dc a65 65 dc j24 24 ac l40 240 ac a24 24 dc j06 6 ac j48 48 ac 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 645 45.000 650 50.000 9 actuator color & legend 5 actuator color i-o on-off dual legend color white a b 1 black black c d 2 white red f g 3 white green h j 4 white blue k l 5 white yellow m n 6 black gray p q 7 black orange r s 8 black
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 21 a-series circuit breaker - rocker C circuit & terminal diagrams notes: 1 all dimensions are in inches [millimeters]. 2 tolerance .020 [.51] unless otherwise specifed. 3 schematic shown represents current trip circuit. 4 circuits shown for >30 amps / vde. circuit & terminal diagrams: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 22 | a-series circuit breaker - rocker - dimensional specifcations notes: 1 dimensions apply to all variations shown. notice that circuit breaker line & load terminal orientation on indicate off is opposite of indicate on. 2 for pole orientation with horizontal legend, rotate front view clockwise 90. 3 all dimensions are in inches [millimeters]. 4 tolerance 0.20 [.51] unless otherwise specifed. dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 23 a-series circuit breaker - rocker snap-in bracket - dimensional specifcations notes: 1 dimensions apply to all variations shown. notice that circuit breaker line & load terminal 2 for pole orientation with horizontal legend, rotate front view clockwise 90. orientation on indicate off is opposite of indicate on 3 recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 all dimensions are in inches [millimeters]. 5 tolerance .020 [.51] unless otherwise specifed. dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 24 | a-series circuit breaker - flat rocker - dimensional specifcations notes: 1 all dimensions are in inches [millimeters]. 2 for pole orientation with horizontal legend, rotate front view clockwise 90. 3 tolerance 0.20 [.51] unless otherwise specifed. dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 25 a-series circuit breaker - recessed paddle - dimensional specifcations notes: 1 all dimensions are in inches [millimeters]. 2 tolerance 0.20 [.51] unless otherwise specifed dimensional specifications: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 26 | a-series circuit breaker - pc terminal diagrams notes: 1 drawing illustrates a-series with vde certifcation. 2 all dimensions are in inches [millimeters]. 3 tolerance 0.20 [.51] unless otherwise specifed pc terminal diagrams: in. [mm]
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 27 sales representatives, distributors & company profle authorized sales representatives and distributors about carling founded in 1920, carling technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. with four iso registered manufacturing facilities and technical sales ofces worldwide, carling technologies sales, service and engineering teams do much more than manufacture electrical components, they engineer powerful solutions! to learn more about carling please visit www.carlingtech.com/company-profle . to view all of carlings environmental, quality, health & safety certifcations please visit www.carlingtech.com/environmental-certifcations click on a region of the map below to fnd your local representatives and distributors or visit www.carlingtech.com/fndarep . europe middle east south america asia-pacific oceania africa mexico usa canada
worldwide headquarters carling technologies, inc. 60 johnson avenue, plainville, ct 06062 phone:f 860.793.9281 fax:f 860.793.9231 email: sales @ carlingtech.com northernfregionfsalesfofce:f nrsm @ carlingtech.com southeastfregionfsalesfofce: sersm @ carlingtech.com midwestfregionfsalesfofce: mrsm @ carlingtech.com westfregionfsalesfofce: wrsm @ carlingtech.com latinfamericafsalesfofce: larsm @ carlingtech.com asia-pacific headquarters carling technologies, asia-pacifc ltd., suite 1607, 16/f tower 2, the gateway, harbour city, 25 canton road, tsimshatsui, kowloon, hong kong phone:f int + 852-2737-2277 fax: int + 852-2736-9332 email: sales @ carlingtech.com.hk shenzhen,fchina:f shenzhen @ carlingtech.com shanghai,fchina:f shanghai @ carlingtech.com pune,findia: india @ carlingtech.com kaohsiung,ftaiwan:f taiwan @ carlingtech.com yokohama,fjapan: japan @ carlingtech.com europe | middle east | africa headquarters carling technologies ltd 4 airport business park, exeter airport, clyst honiton, exeter, devon, ex5 2ul, uk phone:f int + 44 1392.364422 fax:f int + 44 1392.364477 email:f ltd.sales @ carlingtech.com germany:f gmbh @ carlingtech.com france:f sas @ carlingtech.com www.carlingtech.com rev_11_2016


▲Up To Search▲   

 
Price & Availability of AA1-B0-34-615-1B1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X